Model specifications, fault codes
Pump gear setting
When the pump is powered on for the first time, you need to set the desired operating curve by using the operation mode selection button according to actual requirements.
Pump Operation Mode Settings
LD appearance


The digital tube displays the following fault codes:
|
Digital tube |
Fault content |
Fault Description |
Handling measures |
|
E01 |
Indicates overcurrent. |
The motor coil or circuit board is short-circuited or has water ingress. |
Replace the pump motor assembly |
|
E02 |
Indicates idling. |
Air blockage or rotation speed below the set value |
Drain or replace the pump rotor. |
|
E03 |
Indicates locked rotor. |
The rotor is jammed due to a foreign object. |
Disassemble the rotating rotor, remove external forces, and reassemble. |
|
E04 |
Indicates undervoltage |
Input voltage <170VAC |
Wait for the voltage to return to normal and resume operation automatically. |
|
E05 |
Indicates IPM overtemperature. |
IPM module damaged and broken down. |
Replace the control circuit board. |
|
E06 |
Indicates overvoltage |
Input voltage > 290VAC |
The voltage difference drops by 5% and resumes operation. |
|
E07 |
Indicates a software exception. |
The pump motor is running out of control. |
Replace the control circuit board. |
|
E08 |
Indicates phase loss. |
UVW three-phase missing |
Replace the stator coil or the control circuit board. |
Performance curve, gear ratio explanation

|
Model |
Specification dimensions (mm) |
|||||
|
L1 |
L2 |
L3 |
H1 |
Inlet diameter |
Outlet diameter |
|
|
LD125-140180 |
172 |
118 |
152 |
180 |
G11/2 |
G11/2 |
|
LD125-150180 |
172 |
118 |
152 |
180 |
G11/2 |
G11/2 |
|
LD125-170180 |
172 |
118 |
152 |
180 |
G11/2 |
G11/2 |
|
LD125-190180 |
172 |
118 |
152 |
180 |
G11/2 |
G11/2 |
|
LD132-140180 |
172 |
118 |
152 |
180 |
G2 |
G2 |
|
LD132-150180 |
172 |
118 |
152 |
180 |
G2 |
G2 |
|
LD132-170180 |
172 |
118 |
152 |
180 |
G2 |
G2 |
|
LD132-190180 |
172 |
118 |
152 |
180 |
G2 |
G2 |
Electrical data: 1x220~240V, 50/60Hz
|
LD125-140180 |
Rotational speed |
P₁ [W] |
li/1[A] |
|
Minimum |
22 |
0.29 |
|
|
Maximum |
180 |
1.5 |
|
|
LD125-150180 |
Rotational speed |
Pi[W] |
Ii/1[A] |
|
Minimum |
22 |
0.3 |
|
|
Maximum |
220 |
1.6 |
|
|
LD125-170180 |
Rotational speed |
P₁ [W] |
li/1[A] |
|
Minimum |
33 |
0.35 |
|
|
Maximum |
260 |
2.5 |
|
|
LD125-190180 |
Rotational speed |
P₁ [W] |
li/1[A] |
|
Minimum |
38 |
0.35 |
|
|
Maximum |
350 |
2.9 |
Technical Parameters
|
System pressure |
Maximum 0.6 MPa (6 bar) |
Protection rating |
IP44 |
|
Minimum inlet pressure |
0.05 MPa (0.50 bar), at a liquid temperature of 95℃ |
Motor protection |
No external protection required |
|
Liquid temperature |
+2℃~95℃ |
Indicate |
CQC/CE/EEI |
Performance curve
LD1 25-140 180
LD132-140 180
AUTO

|
CP1 - Constant pressure 5m |
CP2 - Constant pressure 6m |
CP3 - Constant pressure 8m |
CP4 - Constant pressure 10m |
PP adaptive |
CC6 - Maximum Curve |
LD125-150 180
LD132-150 180
AUTO

|
CP1 - Constant pressure 5m |
CP2 - Constant pressure 6m |
CP3 - Constant pressure 8m |
CP4 - Constant pressure 10m |
PP adaptive |
CC6 - Maximum Curve |
Electrical data: 1x220~240V, 50/60Hz
|
Rotational speed |
P1 [W] |
I1/1LAJ |
|
Minimum |
22 |
0.3 |
|
Maximum |
220 |
1.6 |
Performance curve, gear ratio explanation
LD125-170 180
LD132-170 180
AUTO

|
CP1 - Constant pressure 6m |
CP2 - Constant pressure 8m |
CP3 - Constant Voltage 10m |
CP4 - Constant pressure 12m |
PP adaptive |
CC6 - Maximum Curve |
Electrical data: 1x220~240V, 50/60Hz
|
Rotational speed |
P1 [W] |
I1/1[A] |
|
Minimum |
33 |
0.35 |
|
Maximum |
260 |
2.50 |
LD1 25-190 180
LD132-190 180
AUTO

|
CP1 - Constant pressure 8m |
CP2 - Constant Pressure 10m |
CP3 - Constant Pressure 12m |
CP4 - Constant pressure 14m |
PP adaptive |
CC6 - Maximum Curve |
Electrical data: 1x220~240V, 50/60Hz
|
Rotational speed |
P1 [W] |
I1/1[A] |
|
Minimum |
38 |
0.35 |
|
Maximum |
350 |
2.9 |
Safety Instructions for Pump Installation and Use