Model specifications, fault codes

Pump gear setting

When the pump is powered on for the first time, you need to set the desired operating curve by using the operation mode selection button according to actual requirements.

 

Pump Operation Mode Settings

LD appearance

The digital tube displays the following fault codes:

Digital tube

Fault content

Fault Description

Handling measures

E01

Indicates overcurrent.

The motor coil or circuit board is short-circuited or has water ingress.

Replace the pump motor assembly

E02

Indicates idling.

Air blockage or rotation speed below the set value

Drain or replace the pump rotor.

E03

Indicates locked rotor.

The rotor is jammed due to a foreign object.

Disassemble the rotating rotor, remove external forces, and reassemble.

E04

Indicates undervoltage

Input voltage <170VAC

Wait for the voltage to return to normal and resume operation automatically.

E05

Indicates IPM overtemperature.

IPM module damaged and broken down.

Replace the control circuit board.

E06

Indicates overvoltage

Input voltage > 290VAC

The voltage difference drops by 5% and resumes operation.

E07

Indicates a software exception.

The pump motor is running out of control.

Replace the control circuit board.

E08

Indicates phase loss.

UVW three-phase missing

Replace the stator coil or the control circuit board.

 

Performance curve, gear ratio explanation

Model

Specification dimensions (mm)

L1

L2

L3

H1

Inlet diameter

Outlet diameter

LD125-140180

172 

118 

152 

180 

G11/2

G11/2

LD125-150180

172 

118 

152 

180 

G11/2

G11/2

LD125-170180

172 

118 

152 

180 

G11/2

G11/2

LD125-190180

172 

118 

152 

180 

G11/2

G11/2

LD132-140180

172 

118 

152 

180 

G2

G2

LD132-150180

172 

118 

152 

180 

G2

G2

LD132-170180

172 

118 

152 

180 

G2

G2

LD132-190180

172 

118 

152 

180 

G2

G2

 

Electrical data: 1x220~240V, 50/60Hz

LD125-140180 
LD132-140180

Rotational speed

P₁ [W]

li/1[A]

Minimum

22 

0.29 

Maximum

180 

1.5 

LD125-150180 
LD132-150180

Rotational speed

Pi[W]

Ii/1[A]

Minimum

22 

0.3 

Maximum

220 

1.6 

LD125-170180 
LD132-170180

Rotational speed

P₁ [W]

li/1[A]

Minimum

33 

0.35 

Maximum

260 

2.5

LD125-190180 
LD132-190180

Rotational speed

P₁ [W]

li/1[A]

Minimum

38 

0.35 

Maximum

350 

2.9 

 

Technical Parameters

System pressure

Maximum 0.6 MPa (6 bar)

Protection rating

IP44

Minimum inlet pressure

0.05 MPa (0.50 bar), at a liquid temperature of 95℃

Motor protection

No external protection required

Liquid temperature

+2℃~95℃

Indicate

CQC/CE/EEI

 

Performance curve

LD1 25-140 180

LD132-140 180

AUTO

CP1 - Constant pressure 5m

CP2 - Constant pressure 6m

CP3 - Constant pressure 8m

CP4 - Constant pressure 10m

PP adaptive

CC6 - Maximum Curve

 

LD125-150 180

LD132-150 180

AUTO

CP1 - Constant pressure 5m

CP2 - Constant pressure 6m

CP3 - Constant pressure 8m

CP4 - Constant pressure 10m

PP adaptive

CC6 - Maximum Curve

 

Electrical data: 1x220~240V, 50/60Hz

Rotational speed

P1 [W]

I1/1LAJ

Minimum

22 

0.3 

Maximum

220 

1.6 

 

Performance curve, gear ratio explanation

LD125-170 180

LD132-170 180

AUTO

CP1 - Constant pressure 6m

CP2 - Constant pressure 8m

CP3 - Constant Voltage 10m

CP4 - Constant pressure 12m

PP adaptive

CC6 - Maximum Curve

 

Electrical data: 1x220~240V, 50/60Hz

Rotational speed

P1 [W]

I1/1[A]

Minimum

33

0.35

Maximum

260

2.50

 

LD1 25-190 180

LD132-190 180

AUTO

CP1 - Constant pressure 8m

CP2 - Constant Pressure 10m

CP3 - Constant Pressure 12m

CP4 - Constant pressure 14m

PP adaptive

CC6 - Maximum Curve

 

Electrical data: 1x220~240V, 50/60Hz

Rotational speed

P1 [W]

I1/1[A]

Minimum

38

0.35

Maximum

350

2.9

 

Safety Instructions for Pump Installation and Use

Keywords

LD Series High-Efficiency DC Inverter Warm Water Shield Pump
LD Series High-Efficiency DC Inverter Warm Water Shield Pump
LD Series High-Efficiency DC Inverter Warm Water Shield Pump
LD Series High-Efficiency DC Inverter Warm Water Shield Pump
LD Series High-Efficiency DC Inverter Warm Water Shield Pump
LD Series High-Efficiency DC Inverter Warm Water Shield Pump
+
  • LD Series High-Efficiency DC Inverter Warm Water Shield Pump
  • LD Series High-Efficiency DC Inverter Warm Water Shield Pump
  • LD Series High-Efficiency DC Inverter Warm Water Shield Pump
  • LD Series High-Efficiency DC Inverter Warm Water Shield Pump
  • LD Series High-Efficiency DC Inverter Warm Water Shield Pump
  • LD Series High-Efficiency DC Inverter Warm Water Shield Pump

LD Series High-Efficiency DC Inverter Warm Water Shield Pump

HWQ-ZJ Stainless Steel Hydraulic Mud Pump


Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit

Related Products

There is no relevant data for the time being, please add it backstage!