U-shaped impeller Vortex impeller, which can generate vortex flow and extract thicker sludge or liquids containing long fibers. |
P-shaped impeller Open impeller, can be divided into single-blade or double-blade impeller, the blade can cut off general foreign objects, prevent solid pollutants from blocking, and reduce the occurrence of pump blockage failures. |
Product Overview
The F-series non-clogging sewage submersible pump (hereinafter referred to as the pump) is composed of three parts: pump, seal, and motor. The motor is located at the top of the pump and is a single-phase or three-phase asynchronous motor. The pump is located below the motor and has a semi-open vortex impeller and volute structure. A double-end face mechanical seal plus a stuffing box oil seal is used between the pump and the motor. The mechanical seal is used for dynamic sealing, and each fixed stop seal uses a "0"-type oil-resistant rubber sealing ring for static sealing. The entire pump uses stainless steel bolts, and the pump casing is treated with electrophoresis plus spraying, effectively isolating air and water, preventing oxidation, and extending service life. The pump is equipped with an external current-type protector, F-class insulation grade, and the cable is waterproofed to prevent the pump from burning out.
Features
● Uses a non-blocking impeller design: It can exert maximum drainage function for sewage containing solid or fibrous materials;
● High-precision motor, high efficiency, the rotating shaft is processed by heat treatment, and the characteristics are stable;
● Motor with external current-type thermal protector: Prevents the pump from burning out during abnormal operation such as overload and jamming;
● The motor uses a new sealing structure, which has good sealing performance and ensures that it will not be damaged during assembly;
● Single-phase motor is equipped with a mechanical centrifugal switch design: Solves the problem of difficult motor starting caused by low voltage;
● All series cables are equipped with rubber cables with waterproof treatment: Prevent water vapor from entering the motor through the cables, avoiding motor dampness and water ingress;
● All cast iron parts use the standard grade gray cast iron 200.
Applications
● Domestic sewage discharge;
● Rainwater accumulation discharge;
● Wastewater treatment in the food, leather, pulp, steel, electronics, and other industries;
● Wastewater treatment in livestock and pig farms.
Operating Conditions
● The pump frequency is 50Hz, the voltage is single-phase AC 220V, three-phase AC 380V;
● The voltage fluctuation range is ±10% of the rated value;
● Operating ambient temperature 0~40°C, the transported medium temperature does not exceed +40°C;
● The transported medium seal ≤1.3x10 3kg/m3;
● The solid content ratio of solid particles in the medium does not exceed 3%;
● Submergence depth does not exceed 5m;
● The pH value of the transported medium is between 4-10.
Model Meaning

Performance Curve

Technical Parameters
Model Specification |
Rated Flow |
Rated Head |
Maximum Flow |
Maximum Head |
Rated Power |
Synchronous Speed |
Rated Voltage V |
Rated Current |
Pipe Inner Diameter mm |
Pump Dimensions |
Passing Particle |
F-21U |
12 |
9.5 |
19 |
15 |
0.75 |
3000 |
220/380 |
7.3/2.7 |
50 |
238×154×458 |
35 |
F-31U |
18 |
7.5 |
32 |
13 |
0.75 |
3000 |
220/380 |
7.3/2.7 |
80 |
275x174x460 |
30 |
F-22U |
12 |
15 |
26 |
20 |
1.5 |
3000 |
220 |
9.5 |
50 |
290x205x568 |
35 |
F-22U |
12 |
15 |
26 |
20 |
1.5 |
3000 |
380 |
3.6 |
50 |
290x205x478 |
35 |
F-32U |
25 |
9 |
42 |
16 |
1.5 |
3000 |
220 |
9.5 |
80 |
262x205x610 |
50 |
F-32U |
25 |
9 |
42 |
16 |
1.5 |
3000 |
380 |
3.6 |
80 |
262x205x520 |
50 |
F-33U |
25 |
12.5 |
50 |
19 |
2.2 |
3000 |
220 |
14 |
80 |
262x205x640 |
50 |
F-33U |
25 |
12.5 |
50 |
19 |
2.2 |
3000 |
380 |
5.1 |
80 |
262x205x540 |
50 |
F-35U |
30 |
16.5 |
59 |
23 |
3.7 |
3000 |
380 |
7.4 |
80 |
262x205x570 |
50 |
F-32P |
36 |
8.5 |
58 |
15.5 |
1.5 |
3000 |
220 |
9.5 |
80 |
275x260x612 |
35 |
F-32P |
36 |
8.5 |
58 |
15.5 |
1.5 |
3000 |
380 |
3.6 |
80 |
275x260x522 |
35 |
F-33P |
36 |
12.5 |
65 |
19 |
2.2 |
3000 |
220 |
14 |
80 |
275x260x642 |
35 |
F-33P |
36 |
12.5 |
65 |
19 |
2.2 |
3000 |
380 |
5.1 |
80 |
275x260x542 |
35 |
F-35P |
36 |
19 |
76 |
27 |
3.7 |
3000 |
380 |
7.4 |
80 |
275x260x572 |
35 |
Installation Dimensions
Model Specification |
H |
H1 |
L |
L1 |
L2 |
W |
DN |
D |
G |
n-M1 |
![]() |
F-21U |
458 |
64 |
238 |
85 |
153 |
154 |
φ50 |
/ |
G2 |
/ |
|
F-31U |
460 |
73 |
275 |
87 |
188 |
174 |
φ80 |
/ |
G3 |
/ |
|
F-22U(220V/50Hz) |
568 |
60 |
290 |
116 |
175 |
205 |
φ50 |
/ |
G2 |
/ |
|
F-22U(380V/50Hz) |
478 |
60 |
290 |
116 |
175 |
205 |
φ50 |
/ |
G2 |
/ |
|
F-32U(220V/50Hz) |
610 |
82 |
402 |
116 |
147 |
205 |
φ80 |
φ150 |
G3 |
4-M14 |
|
F-32U(380V/50Hz) |
520 |
82 |
402 |
116 |
147 |
205 |
φ80 |
φ150 |
G3 |
4-M14 |
|
F-33U(220V/50Hz) |
640 |
82 |
402 |
116 |
147 |
205 |
φ80 |
φ150 |
G3 |
4-M14 |
|
F-33U(380V/50Hz) |
540 |
82 |
402 |
116 |
147 |
205 |
φ80 |
φ150 |
G3 |
4-M14 |
|
F-35U(380V/50Hz) |
570 |
82 |
402 |
116 |
147 |
205 |
φ80 |
φ150 |
G3 |
4-M14 |
|
F-32P(220V/50Hz) |
612 |
122 |
415 |
130 |
145 |
260 |
φ80 |
φ150 |
G3 |
4-M14 |
|
F-32P(380V/50Hz) |
522 |
122 |
415 |
130 |
145 |
260 |
φ80 |
φ150 |
G3 |
4-M14 |
|
F-33P(220V/50Hz) |
642 |
122 |
415 |
130 |
145 |
260 |
φ80 |
φ150 |
G3 |
4-M14 |
|
F-33P(380V/50Hz) |
542 |
122 |
415 |
130 |
145 |
260 |
φ80 |
φ150 |
G3 |
4-M14 |
|
F-35P(380V/50Hz) |
572 |
122 |
415 |
130 |
145 |
260 |
φ80 |
φ150 |
G3 |
4-M14 |
Keywords



F-series non-clogging sewage and sludge submersible pump
Contact Us
Classification